AudioQuest Niagara 5000 Low-Z Power Noise-Dissipation System
- Surge Suppression: Non-sacrificial (nothing to damage with repeated 6000V/3000A input surge tests, which is the maximum that can survive through a building’s AC electrical panel).
- Extreme Voltage Shutdown Voltage: 140VAC (will activate the main high-current relay to open within less than 0.25 second; automatically resets once the incoming power is within a safe range).
- Common-Mode Noise Dissipation: In excess of 30dB from 20kHz to 100MHz, linearized for dynamic (rising) line impedance with frequency (source) and 10 to 50 ohm load, system current dependent.
- Input Current Maximum Capacity: 20 amps RMS (total).
- Ultra-Linear Noise-Dissipation System AC Power Outlet Banks: 4 Isolated groups – total (bank three through six).
- Number of AC Outlets: 12 (4 High Current/Transient Power Correction; 8 Ultra-Linear Noise Dissipation System Power).
- Power Consumption: Typically, less than 0.25 amps at 120VAC input, or with the power correction switched to Standby setting. (This is dependent on a reactive vector load. For more info, see “Operation and Continuous Use: Rear-Panel Power Correction Switch – Niagara 5000 current draw.”)
- 20-amp IEC-C20 main-in power socket requires a power cable with an IEC-C19 connector
-
- Note: Niagara power conditioners do not include an AC power cable
-
Original: $6,900.00
-70%$6,900.00
$2,070.00Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
- Surge Suppression: Non-sacrificial (nothing to damage with repeated 6000V/3000A input surge tests, which is the maximum that can survive through a building’s AC electrical panel).
- Extreme Voltage Shutdown Voltage: 140VAC (will activate the main high-current relay to open within less than 0.25 second; automatically resets once the incoming power is within a safe range).
- Common-Mode Noise Dissipation: In excess of 30dB from 20kHz to 100MHz, linearized for dynamic (rising) line impedance with frequency (source) and 10 to 50 ohm load, system current dependent.
- Input Current Maximum Capacity: 20 amps RMS (total).
- Ultra-Linear Noise-Dissipation System AC Power Outlet Banks: 4 Isolated groups – total (bank three through six).
- Number of AC Outlets: 12 (4 High Current/Transient Power Correction; 8 Ultra-Linear Noise Dissipation System Power).
- Power Consumption: Typically, less than 0.25 amps at 120VAC input, or with the power correction switched to Standby setting. (This is dependent on a reactive vector load. For more info, see “Operation and Continuous Use: Rear-Panel Power Correction Switch – Niagara 5000 current draw.”)
- 20-amp IEC-C20 main-in power socket requires a power cable with an IEC-C19 connector
-
- Note: Niagara power conditioners do not include an AC power cable
-